  1. 53
      SCADA/Program/PanasonicDriver/PanasonicSerialReader.cs
  2. BIN
      SCADA/dll/PanasonicDriver.dll

53
SCADA/Program/PanasonicDriver/PanasonicSerialReader.cs

@ -5,7 +5,6 @@ using System.ComponentModel;
using System.Globalization;
using System.IO;
using System.IO.Ports;
using System.Net;
using System.Text;
namespace PanasonicPLCriver
@ -43,7 +42,7 @@ namespace PanasonicPLCriver
_server = server;
_id = id;
//spare1 = {COM3,9600,Odd,8,One}
_serialPort = new SerialPort("COM2",57600,Parity.Odd,8,StopBits.One);
_serialPort = new SerialPort("COM2", 57600, Parity.Odd, 8, StopBits.One);
_devId = byte.Parse(spare2);
}
public bool IsClosed
@ -299,7 +298,7 @@ namespace PanasonicPLCriver
/// <param name="values">写入的值</param>
/// <param name="respBeginStr">响应的开始帧</param>
/// <returns></returns>
public string CreateWDCmd(int start, short[] values, out string respBeginStr)
public string CreateWDCmd(int start, short[] values, out string respBeginStr)
{
string dataStr = string.Empty;
int size = values.Length;
@ -330,17 +329,18 @@ namespace PanasonicPLCriver
{
if (!isBool(startAddress.Area))//读寄存器的情况
{
cmd = CreateRDCmd(startAddress.Start,size,out respBeginStr);
cmd = CreateRDCmd(startAddress.Start, size, out respBeginStr);
}
else //读触点的情况
{
cmd = CreateRCCCmd(startAddress.Start, size, startAddress.Area, out respBeginStr);
cmd = CreateRCCCmd(startAddress.Start, size, startAddress.Area, out respBeginStr);
}
return WriteSyncData(respBeginStr, cmd);
}
catch (Exception e)
{
OnClose?.Invoke(this, new ShutdownRequestEventArgs(e.Message));
if (OnClose != null)
OnClose(this, new ShutdownRequestEventArgs(e.Message));
return null;
}
}
@ -350,7 +350,7 @@ namespace PanasonicPLCriver
byte[] writeData = Encoding.Default.GetBytes(cmd);
string recv = string.Empty;
lock (syncLock)//这里加锁 防止一个刚写完还没全读来 另一就去写
//但这就会造成锁死的情况 比如循环读的时候 触发去写 这时候必须要等读完才能去写
//但这就会造成锁死的情况 比如循环读的时候 触发去写 这时候必须要等读完才能去写
{
_serialPort.Write(writeData, 0, writeData.Length);
try
@ -359,14 +359,16 @@ namespace PanasonicPLCriver
}
catch (Exception)
{
OnClose?.Invoke(this, new ShutdownRequestEventArgs("读取超时"));
if (OnClose != null)
OnClose(this, new ShutdownRequestEventArgs("读取超时"));
return null;
}
}
}
if (recv.Substring(3, 1) == "!")//返回为错误代码
{
string err = recv.Substring(4, 2);
OnClose?.Invoke(this, new ShutdownRequestEventArgs(daveStrerror(err)));
if (OnClose != null)
OnClose(this, new ShutdownRequestEventArgs(daveStrerror(err)));
return null;
}
string needXorStr = recv.Substring(0, recv.Length - 2);//需要进行xor校验的字符串
@ -374,14 +376,15 @@ namespace PanasonicPLCriver
string checkStr = Utility.XorCheck(needXorStr);
if (checkStr != recvCheck)
{
OnClose?.Invoke(this, new ShutdownRequestEventArgs("校验失败"));
if (OnClose != null)
OnClose(this, new ShutdownRequestEventArgs("校验失败"));
return null;
}
else
{
if (recv.Substring(4, 1) == "W")//如果是写入命令
{
return new byte[0];
return new byte[0];
}
string dataStr = Utility.Pinchstring(recv, respBeginStr, checkStr);
return Utility.HexToBytes(dataStr);
@ -391,7 +394,7 @@ namespace PanasonicPLCriver
{
switch (code)
{
case "20":return "未定义";
case "20": return "未定义";
case "21": return "远程单元无法被正确识别,或者发生了数据错误.";
case "22": return "用于远程单元的接收缓冲区已满.";
case "23": return "远程单元编号(01 至16)设置与本地单元重复.";
@ -430,7 +433,7 @@ namespace PanasonicPLCriver
}
public ItemData<float> ReadFloat(DeviceAddress address)
{
throw new NotImplementedException();
throw new NotImplementedException();
}
public ItemData<short> ReadInt16(DeviceAddress address)
{
@ -475,10 +478,10 @@ namespace PanasonicPLCriver
public int WriteBit(DeviceAddress address, bool bit)
{
string respBeginStr = string.Empty;
string cmd = CreateWCSCmd(address.Start,address.Bit,address.Area,bit,out respBeginStr);
WriteSyncData(respBeginStr, cmd);
return 0;
string respBeginStr = string.Empty;
string cmd = CreateWCSCmd(address.Start, address.Bit, address.Area, bit, out respBeginStr);
WriteSyncData(respBeginStr, cmd);
return 0;
}
public int WriteBits(DeviceAddress address, byte bits)
@ -499,7 +502,7 @@ namespace PanasonicPLCriver
public int WriteInt16(DeviceAddress address, short value)
{
string respBeginStr = string.Empty;
string cmd = CreateWDCmd(address.Start, new short[1] {value}, out respBeginStr);
string cmd = CreateWDCmd(address.Start, new short[1] { value }, out respBeginStr);
WriteSyncData(respBeginStr, cmd);
return 0;
}
@ -609,12 +612,12 @@ namespace PanasonicPLCriver
/// </summary>
public const string WDCmd = "WD";
public const byte Xarea = 0;//外部输入
public const byte Yarea = 1;//外部输出
public const byte Rarea = 2;//内部继电器
public const byte Tarea = 3;//定时器
public const byte Carea = 4;//计数器 不支持
public const byte Larea = 5;//链接继电器 不支持
public const byte Xarea = 0;//外部输入
public const byte Yarea = 1;//外部输出
public const byte Rarea = 2;//内部继电器
public const byte Tarea = 3;//定时器
public const byte Carea = 4;//计数器 不支持
public const byte Larea = 5;//链接继电器 不支持
public const byte DTarea = 6;//数据寄存器 DT
public const byte LDarea = 7;//链接寄存器 LD 不支持

BIN
SCADA/dll/PanasonicDriver.dll

Binary file not shown.